Documentation/ABI/testing/sysfs-bus-iio-adc-hi8435
Source file repositories/reference/linux-study-clean/Documentation/ABI/testing/sysfs-bus-iio-adc-hi8435
File Facts
- System
- Linux kernel
- Corpus path
Documentation/ABI/testing/sysfs-bus-iio-adc-hi8435- Extension
[no extension]- Size
- 1932 bytes
- Lines
- 49
- Domain
- Support Tooling And Documentation
- Bucket
- Documentation
- Inferred role
- Support Tooling And Documentation: Documentation
- Status
- atlas-only
Why This File Exists
Repository support layer: documentation, build tooling, samples, user-space helper tools, generated initramfs support, licenses, and validation utilities.
- Repository support layer: documentation, build tooling, samples, user-space helper tools, generated initramfs support, licenses, and validation utilities.
Dependency Surface
- No C-style include directives detected by the generator.
Detected Declarations
- No top-level syscall, struct, function, initcall, or export declaration detected by the generator.
Annotated Snippet
What: /sys/bus/iio/devices/iio:deviceX/in_voltageY_sensing_mode
Date: August 2015
KernelVersion: 4.2.0
Contact: source@cogentembedded.com
Description:
Program sensor type for threshold detector inputs.
Could be either "GND-Open" or "Supply-Open" mode. Y is a
threshold detector input channel. Channels 0..7, 8..15, 16..23
and 24..31 has common sensor types.
What: /sys/bus/iio/devices/iio:deviceX/events/in_voltageY_thresh_falling_value
Date: August 2015
KernelVersion: 4.2.0
Contact: source@cogentembedded.com
Description:
Channel Y low voltage threshold. If sensor input voltage goes lower then
this value then the threshold falling event is pushed.
Depending on in_voltageY_sensing_mode the low voltage threshold
is separately set for "GND-Open" and "Supply-Open" modes.
Channels 0..31 have common low threshold values, but could have different
sensing_modes.
The low voltage threshold range is between 2..21V.
Hysteresis between low and high thresholds can not be lower then 2 and
can not be odd.
If falling threshold results hysteresis to odd value then rising
threshold is automatically subtracted by one.
What: /sys/bus/iio/devices/iio:deviceX/events/in_voltageY_thresh_rising_value
Date: August 2015
KernelVersion: 4.2.0
Contact: source@cogentembedded.com
Description:
Channel Y high voltage threshold. If sensor input voltage goes higher then
this value then the threshold rising event is pushed.
Depending on in_voltageY_sensing_mode the high voltage threshold
is separately set for "GND-Open" and "Supply-Open" modes.
Channels 0..31 have common high threshold values, but could have different
sensing_modes.
The high voltage threshold range is between 3..22V.
Hysteresis between low and high thresholds can not be lower then 2 and
can not be odd.
If rising threshold results hysteresis to odd value then falling
threshold is automatically appended by one.
Annotation
- Atlas domain: Support Tooling And Documentation / Documentation.
- Implementation status: atlas-only.
Implementation Notes
- This generated page is the file-by-file coverage layer; curated subsystem chapters should link here when they synthesize a multi-file control flow.
- Core OS pages should be promoted from atlas-only to deep-reviewed when they explain data structures, invariants, locking, lifecycle, and C implementation snippets.
- Driver-family pages are intentionally pattern-oriented unless they are part of the selected PCIe/NVMe representative device path.